Ena100 Series Variable Frequency Drive 3 Phase 380V 22kw for Textile Equipment AC Drive

Product Details
Customization: Available
Application: High-performance Transducer, Three Phase Transducer, General Transducer, Single-phase Transducer, High Frequency Converter Transducer
Output Type: Triple
Still deciding? Get samples of US$ 220/Piece
Request Sample
Gold Member Since 2006

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
In-stock Capacity
The supplier has In-stock capacity
Standardized quality control
The supplier has a complete and standardized quality control process, check the Audit Report for more information
to see all verified strength labels (29)
  • Ena100 Series Variable Frequency Drive 3 Phase 380V 22kw for Textile Equipment AC Drive
  • Ena100 Series Variable Frequency Drive 3 Phase 380V 22kw for Textile Equipment AC Drive
  • Ena100 Series Variable Frequency Drive 3 Phase 380V 22kw for Textile Equipment AC Drive
  • Ena100 Series Variable Frequency Drive 3 Phase 380V 22kw for Textile Equipment AC Drive
  • Ena100 Series Variable Frequency Drive 3 Phase 380V 22kw for Textile Equipment AC Drive
  • Ena100 Series Variable Frequency Drive 3 Phase 380V 22kw for Textile Equipment AC Drive
Find Similar Products
  • Overview
  • Product Description
  • Product Advantages
  • Product Specification
Overview

Basic Info.

Model NO.
ENA100
Switch Mode
PWM Control
Main Circuit Type
Voltage
Voltage of Power Supply
Low Voltage Variable-Frequency Drive
Link of Transformation
AC-DC-AC Variable-Frequency Drive
Nature of DC Power
Voltage Variable-Frequency Drive
Function
Simple Type, Textile Special, Constant Torque Universal Type
Brand
Enc
Transport Package
Carton/Wood
Trademark
ENC
Origin
Shenzhen, China
HS Code
8504409999
Production Capacity
200, 000 PCS/Year

Product Description

Product Description

Product Description:
ENA100 is a cost-effective general vector inverter with a power range from 0.4kW to 160kW. Built-in macro functions for typical industry applications, greatly facilitate customer operations. Models below 30KW are equipped with a built-in braking unit as standard. Suitable for higher ambient temperature situations. 

Ena100 Series Variable Frequency Drive 3 Phase 380V 22kw for Textile Equipment AC Drive
Typical application industry:
It is suitable for metal processing, plastic machinery, CNC machine tools, printing equipment, printing and dyeing industry, paper making, municipal engineering, water supply engineering, sewage treatment, etc. lt is also widely used in textile,refrigeration, cement, ceramics, stone processing and other fields.
Ena100 Series Variable Frequency Drive 3 Phase 380V 22kw for Textile Equipment AC Drive
Product Advantages

Product advantages:
  1. Covering sensorless magnetic flux vector control and optimized V/F control, with two modes of speed control and torque control;
  2. Adopting excellent magnetic flux vector control algorithm, high control precision, fast speed response, and excellent low-frequency characteristics, +0.3% rated synchronous speed (vector control without PG); +1% rated synchronous speed (V/F control)
  3. Excellent application macro function, can drive synchronous and asynchronous motors, strong environmental adaptability 50°C without derating, support dual keyboard display, local and remote control keyboards can be used at the same time, small size, high cost performance
  4. Power-on short circuit detection, input and output phase loss protection, over-current protection,under-voltage protection, overheat protection, overload protection, under-load protection, terminal protection, power failure non-stop protection, PlD disconnection protection, water shortage protection.etc.
  5. Support random carrier function, the motor noise is softer
  6. No derating required for 50°C ambient temperature in heavy duty mode
 
Ena100 Series Variable Frequency Drive 3 Phase 380V 22kw for Textile Equipment AC Drive
 

ENA100 Performance advantage:
Two-in-one drive
Motor type: can drive both synchronous and asynchronous motors;
One-key switch between synchronous motor and asynchronous motor, convenient for debugging;
Convenient stocking, effectively shorten the cycle of the warehouse;
ENA100 supports both synchronous and asynchronous motors.

Ena100 Series Variable Frequency Drive 3 Phase 380V 22kw for Textile Equipment AC Drive


Dynamic response:
Torque response:<20ms (without PG quantity control)
Starting torque:1.0Hz, 150% rated torque (V/F control)0.5Hz up to 180% torque (No PG open loop vector)
Control accuracy:±1% rated synchronous speed (V/F control)+0.3% rated synchronous speed (No PG quantity control)

Ena100 Series Variable Frequency Drive 3 Phase 380V 22kw for Textile Equipment AC Drive

Convenient and practical keyboard:
Support dual keyboard display
Support the simultaneous use of local keyboard and external control keyboard
External control keyboard can realize parameter upload and download function
The local keyboard and external control keyboard of traditional inverter can only one to use.
ENA100 local and external control keyboard can be used simultaneously

Ena100 Series Variable Frequency Drive 3 Phase 380V 22kw for Textile Equipment AC Drive
Application macro function:
Built-in multiple application macros, only need to set one parameter for different industries.


Ena100 Series Variable Frequency Drive 3 Phase 380V 22kw for Textile Equipment AC Drive

Structural optimization design:
The difference of power section:
Conventional general series power section :0.4KW~55KW
ENA100 series power section:0.4KW~160KW


Brake unit:
Conventional general series:Three-phase 380V,0.75KW~15KW with built-in brake unit
Three-phase 380V,18.5KW~55KW, optional built- in brake unit

ENA100 series:
Single-phase 220V,0.4KW~2.2KW with built-in brake unit
Three-phase 380V,0.75KW~22KW with built-in brake unit
Three-phase 380V,30KW~160KW, optional external brake unit

No derating at 50ºC and below:
Passed many rigorous tests: salt spray test, high and low temperature impact test, vibration test, ete.
Normal inverter is 30°C, national standard temperature is 40°C, ENA 100 is 50ºC


Ena100 Series Variable Frequency Drive 3 Phase 380V 22kw for Textile Equipment AC Drive

 
Product Specification

Product Specification
 
Item Description


Input

 
Rating volt, frequency 1 phase 220VGrade:1 phase 220V50Hz/60Hz
3 phase380VGrade: 3 phase380V50Hz/60Hz
Allow volt.range 1 phase 220VGrade: 200~260V
3 phase 380VGrade: 320~460V
Output Voltage 0~Input voltage
Frequency 0~600HZ
Over loading capacity Heayy Load:150% of rated current for l minute:Light Load:120% of rated current for 1 minute.
Control 
PerformaAnalog input channelnce
Control mode Without PG vector control, open loop V/F control.
Without PG torque control, support synchronous and asynchronous motors
Velocity control precision +0.3% rated synchronous speed(vector control);
+1% rated synchronous speed(V/F control);
Speed regulation range 1:100(Without PG vector control)
1:50(V/F control)
Start-up torque 1.0Hz: 150% rated torque (V/F control);
0.5Hz:150% rated torque (Without PG vector control);
Speed fluctuation +0.3% rated synchronous speed (Without PG vector control, Without PG torque control); (Without PG vector control)
Torque response ≤20ms(Without PG vector control)
Frequency precision Digital setting: max.Frequency×±0.01%; Analog setting:max.frequency×±0.5%
Frequency
resolution
Analog setting 0.1% of max.frequency
 
Digital setting precision 0.01Hz
Exterior impulse 0.1% of max.frequency
Torque boost Automatic torque boost;manual torque boost 0.1~12.0%
V/F curve(volt. Frequency
characteristic)
Setting rated frequency at the range of 5~600Hz, by choosing constanttorque, degressive torque l, degressive torque 2, degressive torque3, self-defined V/F total 5 kinds of curve.
Acceleration Deceleration curve Two methods: linear acceleration and deceleration and S curve accelerationand deceleration; 15 kinds of acceleration and deceleration time, time unit(0.01s.0.1s.1s)
Brake Power consumption brake ENA100 series three-phase 22KW and below power section has built-in braking unit, only need to add braking resistor between (+)and PB; 30KW and above can connectexternal braking unit between (+) and (-)to achieve Energy consumption braking.
DC brake Start, stop action for option, action frequency 0~15Hz, action current 0~100% of ratedcurrent, action time 0~30.0s
Jog Jog frequency range:0Hz~up limit frequency ; jog acceleration and deceleration time
0.1~6000.0 seconds for setting.
Multi-section speed run Realized by inbuilt PLC or control terminal; with 15 section speed, each section speed with separately acceleration and deceleration time; with inbuilt PLC can achieve reserve when power down.
Built-in PID controller Convenient to make closed-loop control system
Automatic energy saving run Optimize V/F curve automatically to achieve power saving run according to the load status.
 

Control performance
 
Automatic voltage regulate(AVR) Automatically keep output voltage constant, when the power grid voltage fluctuation
Automatic current limiting Current limited automatically under run mode in avoid of inverter over-current frequently to trip
Carrier modulation Make rotating motor smoothly start without shocking
Speed tracking restart Make rotating motor smoothly start without shocking
Running function Running command specifed channel Keypad specified, control terminal specifed, communication specifed can switch through various means
Running frequency specified channel Main & auxiliary specifed to a realize one main adjusting and one fine control. Digital specifed, analog specified, pulse specifed, pulse width specifed, communication specifed and others, which can be switched by many means at any time.
Binding function Run command channel and frequency specified channel can bind together randomly and switch synchronously
Input and output characteristics Digital input channel 5 general-purpose digital input channels, the maximum frequency is lKHz, one of which can be used as a pulse input channel, the maximum input is 20KHz
Analog input channel 2 analog input channels, of which All is 0~10V output, AI2 channel is 0~20mA or 0~10V input optional.
Pulse output channel 0.1 ~20KHz pulse square signal output to achieve setting frequency, output frequency andother physical quantity output.
Analog output channel 1 analog signal output, AOl channel can choose 0~20mA or 0~10V to realize the output of physical quantities such as set frequency and output frequency
Digital output 2 Y outputs, Y2 can achieve the highest frequency output of 20K, 1 Rel output
Unique function Rapid current limit Limit inverter over current to the greatest point, and make it run more stably
Monopulse control Suitable for working site where need one button to control inverter start and stop,first press to start, then press to stop, and that cycle repeats. Its very simple and reliable.
Fixed length control Realize fxed length control
Timing control Timing control function: setting time range 0.1Min~6500.0 Min
Virtual terminal Five group virtual input & output lO can realize simply logical control
Operation keyboard Keyboard display The parameters as setting frequency, output frequency, output voltage, output current canbe displayed
Button locked Lock all or part ofthe buttons
Dual keyboard control Can use external keyboard to achieve dual keyboard control (local and remote control)
Dual keyboard control Motor power on Shot circuit test, input & output phase loss protection, over-currentprotection, over voltage protection, under voltage protection, over heat protection,overload protection, under load protection, relay absorption protection, terminalprotection and no stop protection under power of.
Ambient Application site Indoor, not bare to sunlight, no dust, no corrosive gas, no flammable gas, no vapor, nowater drop or salt etc.
Altitude Under 1000 meter. (above 1000 meter require to reduce volume to use, output currentreduce about 10% of rated current volt per 1000 meter high)
Environment temperature -10ºC~+50ºC
Environment humidity Smaller than 95%RH, no drop condenses
Vibration Smaller than 5.9 M/S2(0.6g)
Storage temperature -40ºC~+70ºC
Structure Protection grade IP20
Cooling mode Forced air cooling and natural
Installation mode Wall hanging and cabinet installation

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier